Troubleshoot Offline Camera - NVR IPCAMERA SECURITY
How To FAQ Guide Troubleshooting

Troubleshoot Offline Camera

Troubleshoot Offline Camera
Troubleshoot Offline Camera

Troubleshoot Offline Camera, Are your cameras offline? Use this guide to fix the issue. When one of your cameras is offline, you are unable to view recorded video and may not be able to see your camera live on any of your monitors on location.Here are some signs that you camera has gone offline:

• The local monitor(s) in your office/location show a black square or displays a NO VIDEO message where the camera is supposed to be:

• From the Video page in the Solink platform, you can hover over your locations to display camera information and determine whether your cameras are offline:

• You are not able to load video on the mobile apps or web application.
• One or more of your Solink Video Alarm cameras displays as offline:

What to do When Your Camera is Offline

The Solink support team is ready to help. Our team works with your location(s) to troubleshoot camera issues so that you can get back to recording as soon as possible. To do this, we check the following, based on your camera type:

Troubleshoot Offline Camera

IP Cameras: What to Look For

Solink support can identify what type of camera you have. IP cameras usually have one Ethernet cable connected to the camera.

These types of cameras optimize connection by getting power (Power over Ethernet, or POE for short) and transmitting data (sending data to the Solink system) over a single cable. A typical IP camera and Ethernet connection looks like this:

An Ethernet cable’s end looks like this:

Each camera will have an Ethernet cable that connects into a POE switch. In most environments, the switch will look similar to the following:

How to Troubleshoot an Offline IP Camera

Once you have found the POE switch, ensure that:

• All connections are securely fastened.
• The POE switch has lights for each cable (both on the cable, and on the LED panel on the front – normally, each port has one light for Link, and one for POE.
• No cables have broken ends/clips.

If everything is connected tightly and all cables have lights, you can attempt to restart the POE switch. Sometimes, a camera may become “frozen” and need a physical reboot.

Note: If you know which cable goes to the specific camera you need to troubleshoot, you can unplug and replug the cable. This is the same as rebooting the switch. Rebooting the POE switch causes all cameras to go offline for a short period of time until it powers back up fully.

If the camera still does not come back online after a physical reboot, it is possible that there is an issue on the camera end – either the cable is broken between the switch and the camera, the cable is unplugged at the camera side, or the camera itself has physical damage or defects. Solink support can assist with confirming this.

.

Analog Cameras – What to Look For

Solink support can identify if your cameras are analog. Analog cameras usually have 2-3 cables attached – one for power, one for video signal, and one (optional) for an audio signal.

The different cables look similar to the following image:

If your cameras are analog, Solink supplies an analog encoder to your location. This device converts the old analog signal into digital so that we can record it properly on our system. A standard analog encoder is displayed in the following image:

Your analog camera video cables are connected to the rear side of the encoder.

The power cables for your analog cameras are usually wired to a CCTV power supply box, or are plugged into a UPS. The image below displays an example of a CCTV power supply box:


How to Troubleshoot an Offline Analog Camera

If an analog camera is offline, you will either see NO VIDEO text on the Solink interface (and Live Monitor, if applicable), or a black screen for some models. In this case, check the following:

• Ensure all cables are properly connected to the analog encoder. BNC cables are round and silver and connect to the rear side of the encoder.
• Ensure that the CCTV power supply is either plugged in properly; or if you are using a breaker box, ensure it is powered on and there are lights on all connections within the box.

If all cables are tightly connected and power seems to be working for all cameras, you may require an on-site technician. It is possible that the cabling, cable ends (BNC), power supply, or the camera itself has an issue or defect. Solink support can assist.

.

Status of the Solink Software

Solink support can help confirm that there are no issues with the Solink interface itself that would cause a camera to stop recording. Please feel free to reach out to us at any time to confirm if there are any issues.

Troubleshoot Live Monitor

Troubleshoot Live Monitor

Is your live monitor down? Use this guide to troubleshoot.

If you encounter any of the following issues, please read the instructions in this section to attempt to troubleshoot the issue or reach out to our support team via live chat, phone or email.

No Input/Blank Screen

If the live monitor displays no input or a blank screen, try troubleshooting the issue with the following steps:

1.Check if the recording device is turned on. If not, turn the device on (this could take up to 10 minutes). The photos below display two different models of the recording device, for reference:
2.

2. If the recording device is on but the live monitor is still not working, ensure the cables are connected correctly; you should have an HDMI cable connected to HDMI port 1 or port 2. Additionally, follow the cord and ensure that it is securely plugged in to your monitor as well.

3. Reboot the HDMI/VGA adapter (the device shown in the following image). To reboot this device:

• Locate the VGA/HDMI adapter on the cord between the recording device and the monitor.
• Unplug both sides of the cord and wait 20-30 seconds.

If you followed the steps above and the issue still persists, please contact our support team via live chat, phone or email:

• Live Chat: Available in the bottom corner of the Solink platform, Help Center, mobile apps, and our website

TurboNAS Login Screen

Please let the support team know if this screen is displayed. Use live chat or send the team an email at How To Setup Nas For Hikvision Ip Camera

Frozen Cameras

If any cameras are frozen on your live monitor, try the following steps to troubleshoot the issue:

1.Navigate to the Video page.
2.Each of your locations display the number of online cameras. Additionally, if you hover over a location, a health indicator displays to inform you of any offline cameras. In the following image, the health indicator is showing that the store has 21 out of 22 cameras online and which camera is offline:

3. If all cameras are online and your device is online or offline – please contact our support team using the information at the bottom of this section.

If some cameras are offline, please follow the steps in Troubleshoot Offline Camera.

As always, you can contact our support team with the following methods:

offline camera, camera not working, camera troubleshooting, camera error, security camera problems

IP camera offline, offline, CCTV camera offline, surveillance camera offline, security system troubleshooting

why is my camera offline, , , , camera lost connection

camera power supply, network connection, , firmware update,

camera black screen, camera frozen, camera no image, , camera not recording

security camera, IP camera, WiFi camera, CCTV, , troubleshooting

my IP camera is offline, how to fix a camera that won’t turn on, camera keeps going offline, camera not showing live view, camera not recording to NVR

smart home, IoT, home security, surveillance, network troubleshooting, device connectivity

camera troubleshooting guide, camera troubleshooting tips, , camera maintenance,

About the author

M.Salih ASLAN

Hello, I live in Salih Turkey. I serve in dvr, nvr, security and surveillance industry. Write to me for any comments and suggestions ..

Add Comment

Click here to post a comment